Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Oral Maxillofac Implants ; 30(1): 73-94, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25615917

RESUMO

PURPOSE: The purpose of this systematic review was to identify studies in which either orthodontic extrusion or bone grafting was used prior to single implant placement in the maxillary esthetic zone and to compare the biologic, functional, and esthetic outcomes of these two approaches. MATERIALS AND METHODS: An electronic MEDLINE search was conducted by three independent reviewers to identify English-language articles, published in dental journals between January 1992 and August 2013, reporting on single-implant site development accomplished by orthodontic forced eruption of nonrestorable teeth or by bone grafting procedures. The search terms were categorized into four groups comprising a PICO (problem, intervention, comparison, outcome) question. Supplementary manual searches of published full-text articles and related reviews were also performed. RESULTS: The initial database search produced 301 relevant titles. After careful examination and discussion, 32 studies were selected for inclusion. No study directly comparing the two implant site-development methods was identified. The observation periods of the available studies were either short or not stated. CONCLUSION: There is a substantial lack of evidence to determine which method for implant site development is better. Definitive conclusions cannot be drawn, since no clinical trials have directly compared these two methods. All included studies reported separately on the two implant site-development methods and used different protocols. According to the literature reviewed, it seems that both methods of implant site development are effective and neither method is superior. Multicenter studies and randomized clinical trials should be performed to evaluate the efficacy of these two methods.


Assuntos
Transplante Ósseo/métodos , Implantação Dentária Endóssea/métodos , Estética Dentária , Maxila/cirurgia , Humanos
2.
J Prosthet Dent ; 112(1): 70-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24674809

RESUMO

STATEMENT OF PROBLEM: Different inlay casting waxes do not produce copings with satisfactory marginal accuracy when used on different die materials. PURPOSE: The purpose of this study was to evaluate the marginal accuracy of 4 inlay casting waxes on stone dies and titanium and zirconia abutments and to correlate the findings with the degree of wetting between the die specimens and the inlay casting waxes. MATERIAL AND METHODS: The inlay casting waxes tested were Starwax (Dentaurum), Unterziehwachs (Bredent), SU Esthetic wax (Schuler), and Sculpturing wax (Renfert). The marginal opening of the waxes was measured with a stereomicroscope on high-strength stone dies and on titanium and zirconia abutments. Photographic images were obtained, and the mean marginal opening for each specimen was calculated. A total of 1440 measurements were made. Wetting between die materials and waxes was determined after fabricating stone, titanium, and zirconia rectangular specimens. A calibrated pipette was used to place a drop of molten wax onto each specimen. The contact angle was calculated with software after an image of each specimen had been made with a digital camera. Collected data were subjected to a 2-way analysis of variance (α=.05). Any association between marginal accuracy and wetting of different materials was found by using the Pearson correlation. RESULTS: The wax factor had a statistically significant effect both on the marginal discrepancy (F=158.31, P<.001) and contact angle values (F=68.09, P<.001). A statistically significant effect of the die material factor both on the marginal adaptation (F=503.47, P<.001) and contact angle values (F=585.02, P<.001) was detected. A significant correlation between the marginal accuracy and the contact angle values (Pearson=0.881, P=.01) was also found. CONCLUSIONS: Stone dies provided wax copings with the best marginal integrity, followed by titanium and zirconia abutments. Unterziehwachs (Bredent), wax produced the best marginal adaptation on different die materials. A significant correlation was found between the marginal accuracy and the contact angle values. As the contact angle value became smaller, the marginal accuracy improved. All combinations of waxes and stone and titanium dies presented a high wettability.


Assuntos
Sulfato de Cálcio/química , Dente Suporte , Materiais Dentários/química , Moldagem de Cera para Incrustações/química , Titânio/química , Zircônio/química , Adaptação Marginal Dentária , Humanos , Processamento de Imagem Assistida por Computador/métodos , Teste de Materiais , Fotografação/métodos , Polimetil Metacrilato/química , Propriedades de Superfície , Molhabilidade
3.
Case Rep Dent ; 2013: 378062, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24383012

RESUMO

Restoration of single tooth loss with implant supported prosthesis is now considered a highly predictable treatment. However, the maxillary anterior region still presents a challenge for both the prosthodontist and the periodontist because of the inherent difficulties encountered in the provisionalization and harmonic incorporation of the definitive prosthesis into patient's dentogingival complex. This paper presents a clinical case of a single implant placed immediately after the extraction of a maxillary central incisor, followed by immediate provisionalization and nonfunctional loading. The surgical and the restorative techniques are described, and the parameters of consideration for this approach are presented.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...